Gaylord Archival Boxes Testing as Acidic?

  • 1.  Gaylord Archival Boxes Testing as Acidic?

    Posted 09-24-2019 00:59
    Hi Collections Community,

    I was recently showing a student how to tell the difference between an acid-free storage box and an acidic one using the Lineco pH Testing Pen and we realized that the Gaylord box (Product #: TC1215) listed as acid-free is acidic according to the pen. Has anyone else noticed this? I'm going to reach out to Gaylord Archival to see what they have to say, but wanted to make others aware of this potential problem.

    Thanks,
    Siri Linz

    Here is the link for the product: 

    https://www.gaylord.com/Preservation/Document-Preservation/Record-Storage-Cartons/Gaylord-Archival%26%23174%3B-C-flute-Acid-Free-Record-Storage-Carton/p/TC1215


    ​

    ------------------------------
    Siri Linz
    Assistant Archaeology Collections Manager
    Burke Museum
    Seattle WA
    (206) 685-3849 (2)
    ------------------------------


  • 2.  RE: Gaylord Archival Boxes Testing as Acidic?

    Posted 09-24-2019 15:11
    Hi There - I've also noticed that our hollinger archival boxes read as acidic (below a ph level of 7) when I've tested with this pen: pH Indicator Pen | Carr McLean
    I actually wondered if it was the pen that was faulty and not the boxes. I'm unsure how accurate these pens are in comparison to a more thorough testing method. 


    ------------------------------
    Claire Forsyth
    Archivist
    Memory Labs
    Toronto ON
    ------------------------------



  • 3.  RE: Gaylord Archival Boxes Testing as Acidic?

    Posted 09-25-2019 15:03

    Some acid-free tissue (brand new, freshly opened pack) has tested with a low pH from Lineco pH pen and a pH pen bought from a crafting store.  Several packs of standard printer/copier paper tested neutral.

     

    I'm wondering if the surface finish on the tissue is affecting the result?

     

    With best wishes

    Helena

     

    Helena Jaeschke

    Conservation Development Officer

    South West Museum Development Programme

    www.southwestmuseums.org.uk

     

     

     

    See our privacy notice for details on how we manage personal information.

    Disclaimer: http://www.exeter.gov.uk/disclaimer



    ------Original Message------

    Hi There - I've also noticed that our hollinger archival boxes read as acidic (below a ph level of 7) when I've tested with this pen: pH Indicator Pen | Carr McLean
    I actually wondered if it was the pen that was faulty and not the boxes. I'm unsure how accurate these pens are in comparison to a more thorough testing method. 


    ------------------------------
    Claire Forsyth
    Archivist
    Memory Labs
    Toronto ON
    ------------------------------


  • 4.  RE: Gaylord Archival Boxes Testing as Acidic?

    Posted 09-25-2019 15:04

    Hi everyone,

    We've noticed that acid-free unbuffered tissue from Gaylord also tests positive with the pH testing pen from Lineco. We wondered if the tissue, which ships on an acidic tube, might have migrated to the tissue. We've tested several roles (both new, and partially-used) and received the same result.

    If the pH testing pens aren't an accurate method of testing, what is a preferable alternative?

    Thank you,

    Rebekah



    ------Original Message------

    Hi There - I've also noticed that our hollinger archival boxes read as acidic (below a ph level of 7) when I've tested with this pen: pH Indicator Pen | Carr McLean
    I actually wondered if it was the pen that was faulty and not the boxes. I'm unsure how accurate these pens are in comparison to a more thorough testing method. 


    ------------------------------
    Claire Forsyth
    Archivist
    Memory Labs
    Toronto ON
    ------------------------------


  • 5.  RE: Gaylord Archival Boxes Testing as Acidic?

    Posted 02-13-2020 11:47
    Remember a pH pen is limited to surface readings so doing a cold or hot extraction would be more accurate, however destructive. The pen only reads superficially so the coating will affect your read and be aware that the outer paper will also become acidic first as there is acid migration. The pH in an environment will naturally go to a neutral state, the buffered paper turns acidic and vice-versa, and why buffering helps slow down deterioration. The buffered papers/boards do have a life expectancy depending on its contents and its storage environment. Most likely both have some issues, most items saved in these boxes from library and archives are not good quality paper and therefore tend to be acidic.

    ------------------------------
    Cher Schneider
    ------------------------------



  • 6.  RE: Gaylord Archival Boxes Testing as Acidic?

    Posted 09-25-2019 15:06
    The box you are testing had a neutral pH when it was manufactured (according to the specs) . It's not buffered with a calcium carbonate reserve and it's not lignin-free. A paper board that still has lignin in it will become more acidic over time as the lignin breaks down. So this type of box may be neutral in pH when it leaves the factory, but is unlikely to remain so for very long.

    A pH pen that basically just tests whether a paper material is above or below pH 6.5 (which is apparently the key level for this chlorophenol red based pen) is often going to show "acidic" for such a box. So the pen works just fine and the box is within specs.

    But the larger question is, what is the purpose of such a pH pen test? It would seem to me that a lignin testing pen would be a much better indicator of paper quality / suitability for archival purposes. The idea of choosing whether a box is suitable based on being above or below pH 6.5 sounds like an idea straight out of the 1970s perpetuated by archival companies' need to sell a pen. But I hope others will speak up if there are situations where such a test is meaningful for preservation purposes.

    Though even a lignin pen would be of limited use for all but the most stringent of requirements, since small amounts of lignin are clearly acceptable for many archival applications (such as this "acid free box" that you tested).

    In the end, it seems that the more practical approach is to simply buy your archival materials from a trusted supplier.

    best,
    Gawain



    ------------------------------
    Gawain Weaver
    Photograph Conservator
    Gawain Weaver Art Conservation
    San Francisco Bay Area
    (415) 446-9138
    Free Process ID Charts: http://gawainweaver.com/processID
    ------------------------------



  • 7.  RE: Gaylord Archival Boxes Testing as Acidic?

    Posted 02-07-2020 11:01
    Hello all,

    I would like to resurrect this thread. When I originally read this post, I was shocked and stored this info to look into at a later time. I have since acquired a complimentary Abbey pH Pen from Hollinger after I called them to check on some 20+ year old boxes. The sales rep I spoke to indicated she did not recognize the boxes in the 20 years she worked there after looking at the photo I sent. So she sent us a pen and lo and behold all of them test as acidic. We order our supplies from Gaylord, and so far all those boxes test as acid free with the exception of the unbuffered tissue confirming Rebekah's findings.

    Here is my issue - does this mean all our supplies have a life expectancy and we should plan to replace all our boxes in the future? This seems like it should be something that the archives profession would have been aware of. Perhaps our Holligner boxes are counterfeit copies. Who knew that there would be a black market for archival materials?! All joking aside, I would like to hear what others think. In the meantime, I plan to reach out to LOC since they test all their materials.

    ------------------------------
    Meghan Bailey
    Processing Archivist
    UMass Boston University Archives and Special Collections
    (617) 287-5946
    ------------------------------



  • 8.  RE: Gaylord Archival Boxes Testing as Acidic?

    Posted 02-09-2020 16:15
    Keep in mind that the 'archival' boxes are acting as filters for pollutants in the atmosphere. Therefore they do become acidic overtime and require replacement if you want to maintain the filtering characteristic of your enclosures. The boxes that have become acidic are not going to start releasing the acids into the atmosphere within the box. However, there is a possibility that the acids will migrate through the box and cause acid hydrolysis deterioration in any materials that are in direct contact with the box. Basically the 'filter' is full and needs to be replaced, but it is still acting as a barrier from additional airborne pollutants.


    ------------------------------
    Kyla Ubbink
    Principle Conservator/Proprietor
    Ubbink Book and Paper Conservation
    Ottawa ON
    (613) 523-0569
    ------------------------------



  • 9.  RE: Gaylord Archival Boxes Testing as Acidic?

    Posted 02-11-2020 11:21
    Per Gawain's post, the supplier's specs for that product clearly state the product is unbuffered and contains lignin.  Gotta read those specs!  The primary description says "economical way to transport collections or store documents in the short term."  It's incumbent on the consumer to do their homework and figure out the best product for the specific purpose.  Don't just buy the cheapest box if you plan to use it for long-term storage.  I've found Gaylord and Hollinger, vendors mentioned in this thread, to be highly reputable.  

    The LoC website has a Preservation homepage that includes an article called "The Deterioration of Paper: Some Essential Facts".  There's a long list of external and internal factors that contribute to cellulose degradation which manifests as a drop in pH.  Cellulose itself generates acid as it ages.  Highly processed, short-fiber, unbuffered paper products, like glassine and tissue, will become acidic fairly quickly even tho they were acid-free when they left the mill.  Yes, your supplies do have a life expectancy, as do your collections.  But maybe slightly acidic tissue is fine for transporting ceramics from a gallery to the conservation lab.

    The LoC also has a very useful page called Preservation Supply Specifications with a lengthy list of materials for storage. See Specification 600-612-16 Corrugated Board for Protective Enclosures,.  I'm sure there's an equivalent home page on the National Archive website.  All of this info is out there and easily accessible.
    ​​

    ------------------------------
    Pamela Young
    Senior Paper Conservator
    Colonial Williamsburg Foundation
    Williamsburg VA
    (757) 565-8761
    ------------------------------



  • 10.  RE: Gaylord Archival Boxes Testing as Acidic?

    Posted 02-12-2020 09:49
    Hi Pamela, et al.

    All your replies have been very helpful. I have also cross posted on the SAA preservation list serv and had some helpful responses. To be clear my institution does not use the boxes that was originally posted in this thread. We use the Gaylord record cartons like this one which is lignin-free and "provides safe, long-term storage..." I think Kyla's explanation makes the most sense - the box acting as a filter to what is in the atmosphere. I received similar replies from the SAA list serv. I find it interesting that this is not something anyone talks about in the archive profession. I think it's easy to take for granted that archival supplies are good to go- especially if they are marketed as "safe long-term storage." I will be sharing this info with my colleagues! If anyone has something to add I am all ears! Thanks!!

    ------------------------------
    Meghan Bailey
    Processing Archivist
    UMass Boston University Archives and Special Collections
    (617) 287-5946
    ------------------------------



  • 11.  RE: Gaylord Archival Boxes Testing as Acidic?

    Posted 02-14-2020 12:57
    Dear Megan et al.

       Testing boxes requires knowing their age and the conditions under which they have been stored or will be stored.  Aging has a remarkable effect on the components and you want to know how there interaction as they age will affect the materials (documents, photos, etc.) you will put in them.  Bob Futernick and I tested a number of storage boxes, including Solander boxes, and other manufacturer types, as well as boxes that were as old as 40 years.  We placed some boxes in extreme conditions (sun, damp, etc.) and then tested the components and the environments in the boxes.  We published our results:

    1994      Storage conditions and physical treatments relating to the dating of the Dead Sea Scrolls, Radiocarbon,

    1.   37, #1, 1994:21-32.

    This is obviously a bit dated but I think the materials of most boxes are the same and it provides a base line as well as a bibliography on earlier testing of boxes.

    Niccolo

    ------------------------------
    Niccolo Caldararo
    Director and Chief Conservator
    Conservation Art Service
    San Francisco CA
    (415) 453-9064
    ------------------------------